The module spec sheet tells you the electrical and mechanical numbers. This article is about what to do with them, because in our experience the first time a radar product fails a test lab, the cause is almost never the sensor — it is the supply, the ground, or the enclosure sitting too close to the antenna.

Everything below applies to the three bare modules we sell. Where a value differs per module it is stated; where the datasheet is the authority, it says so.

Power: the window, the current, and the ripple

Module Supply Current Ripple
R60AFD1-V (fall, 60 GHz) 4.5–5.5 V, typ. 5.0 V ≤ 100 mA avg, ≤ 300 mA peak ≤ 100 mV
R60ABD1 (sleep & breathing, 60 GHz) 4.5–5.5 V, typ. 5.0 V ≥ 200 mA ≤ 100 mV
R24AVD1 (presence, 24 GHz) see datasheet see datasheet see datasheet

Three things to take from that table:

Practical layout order: bulk reservoir → LDO → module VCC, with the decoupling capacitor as close to the module pins as the layout allows. Keep the supply trace short and direct; do not route it past a relay coil or a motor driver.

Two power domains, and they stay separate

If your product switches a load — a light, an HVAC contactor, a buzzer — the module and the load live in separate power domains, as shown in the presence relay article and the PLC dry-contact article:

   Module domain                 Load domain
   5 V, clean  ──► radar          5/12 V ──► relay ──► load
        │                              │
        └──────── single-point ────────┘
                  ground

The enclosure is part of the antenna

The 60 GHz modules radiate through their own PCB. The housing around them is part of the RF path, which is why the mounting notes in the guides read like RF instructions:

If your product has a lens or radome over the antenna, treat its material and thickness as a design variable and confirm the effect with your own measurements rather than assuming.

EMC basics that matter for this sensor

The radar is a sensitive receiver sitting next to whatever else your product contains. In order of impact:

  1. Distance from switching power. Keep the switcher, its inductor, and its loop area away from the antenna end of the board. This is the single biggest source of broadband noise in a compact product.
  2. Motors and solenoids. A buzzer, a lock, or a fan in the same enclosure couples straight into the measurement. If they must share a board, keep them at the far end and give them their own return path.
  3. Cable routing. Keep the UART pair and any GPIO wires away from the supply wires and from anything switching current. Twist the UART pair if the run is long.
  4. Antenna area is keep-out. No traces, no vias, no pours under or beside the antenna unless your design rules explicitly allow it.
  5. Ground discipline. One solid ground reference for the analog/sensor domain; noisy return currents kept off it.

Why your lab will ask about all of this

These are the same items that decide whether the product passes. The enclosure and the supply determine radiated emissions and band-edge behaviour, and the lab will want your technical file to reflect the configuration you actually ship. The full picture is in Certification Support: Get CE and FCC Made Out to Your Own Name — including what we supply and what stays yours.